Thermometers, thermocouples, RTDs, dry-block sources, and temperature indicators

1925 products

Wireless surface / ambient temperature monitor — part of Emerson's Synchros IIoT platform for asset and condition monitoring. WirelessHART (IEC 62591) protocol, integrates with existing or new WirelessHART networks via a 1410S Gateway. Designed for asset-level trend monitoring (heat exchanger fouling detection, heat trace verification, reciprocating compressor valve health, distribution line monitoring). User-orderable with battery, integral thermocouple sensor, and mounting accessories — all in one model number. Mount options: bracket, pipe clamp (magnetic mount coming). Designed for hazardous-area service. Connects to Plantweb Insight Asset View for real-time alerts, trend charts, and asset health scoring.

Specialty barstock thermowell with a patented twisted-square stem profile that dramatically reduces vortex-induced vibration. Designed for high-velocity service where a straight or tapered stem would resonate and fail by fatigue. ASME PTC 19.3 TW-2016 compliance for vortex-induced stress mitigation. Same 114C platform as the standard barstock thermowell, but with Threaded mounting only and the unique Twisted stem style. Wide material selection: 316/316L SST, 304/304L SST, Carbon Steel A-105, 310 SST high-temp, 321 SST, Alloy B-3, Alloy C-276 (Hastelloy). Immersion length 2-40 in / 50-1000 mm.

-50…350 °C · Current output (2-wire), Switching output · M12 × 1

-50…120 °C · Resistance · G 1/8'' male thread

-50…120 °C · Resistance · G 1/8'' male thread

-50…120 °C · Resistance · 1/4″ NPT

-50…120 °C · Resistance · 1/4″ NPT

-50…120 °C · Resistance · For compression fittings, thermowell or direct mounting

-50…500 °C · Resistance · For compression fittings, thermowell or direct mounting

-50…500 °C · Resistance · For compression fittings, thermowell or direct mounting

-50…500 °C · Resistance · For compression fittings, thermowell or direct mounting

-50…500 °C · Resistance · For compression fittings, thermowell or direct mounting

-50…500 °C · Resistance · For compression fittings, thermowell or direct mounting

-50…500 °C · Resistance · For compression fittings, thermowell or direct mounting

-50…500 °C · Resistance · For compression fittings, thermowell or direct mounting

-200…500 °C · Resistance · For compression fittings, thermowell or direct mounting

-50…120 °C · Resistance · For compression fittings, thermowell or direct mounting

-50…500 °C · Resistance · For compression fittings, thermowell or direct mounting

-50…500 °C · Resistance · For compression fittings, thermowell or direct mounting

-50…500 °C · Resistance · For compression fittings, thermowell or direct mounting

-50…500 °C · Resistance · For compression fittings, thermowell or direct mounting

-50…500 °C · Resistance · For compression fittings, thermowell or direct mounting

-50…500 °C · Resistance · For compression fittings, thermowell or direct mounting

-50…500 °C · Resistance · For compression fittings, thermowell or direct mounting