Flowmeters, level transmitters, level switches, and flow indicators
342 products

1/4″ NPT-18 male thread · 10…30 VDC

SNORKEL sanitary pressure and level transmitter, fixed range. Configured to order — base list price shown.

Submersible hydrostatic level probe for tanks, deep wells, and piezometers. Any measurement range from 1 to 500 m H2O, integrated overvoltage protection, vented-capillary cable, ATEX intrinsic safety, DNV marine certificate.

Small diameter submersible hydrostatic level transducer. Configured to order — base list price shown; specify range, cable length, output.

Complete liquid-level measurement system — a 316 stainless steel snubnose AMETEK submersible transmitter paired with a fully calibrated, microprocessor-based meter/controller in a NEMA 4X housing, plus factory-installed waterproof cable. Choose the sensor model (575, 575 PB, 675 PB, 375, SST, or SDT), meter output (two or four relays, optional 4–20 mA), and lightning protection. The specific sensor range is included at no charge and cable length is quoted separately. Configure sensor, output, and lightning protection.

Cost-effective submersible level transmitter for tanks, wells, and wastewater. 4–20 mA or 1–5 VDC output, ranges 0–6 to 0–300 PSI (to ~692 ft of water), 316L stainless steel diaphragm, a Delrin or stainless snubnose or flush sensing port, and vented polyurethane cable with a Viton seal. Cable length is specified separately. Configure sensing port, output, range, and electrical connection.

Submersible pressure transmitter for liquid-level measurement in tanks, wells, sumps, and wastewater. 12–28 VDC / 4–20 mA output, ranges 0–6 to 0–300 PSI (to ~692 ft of water), with a choice of snubnose, stainless snubnose, or protected flush-cage sensing port; 316 stainless steel or Hastelloy C diaphragm; and polyurethane or Teflon cable. NSF-certified and CSA intrinsically safe versions available. Cable length is specified separately. Configure sensing port, range, electrical connection, diaphragm, and fill.

Shark Cage submersible level transmitter — a rugged flush-diaphragm sensor inside a protective cage for debris-laden or high-flow service such as lift stations, storm water, and industrial sumps. CSA intrinsically safe. 12–28 VDC / 4–20 mA output, ranges 0–6 to 0–60 PSI, 316 stainless steel diaphragm, and vented polyurethane or Teflon cable. Cable length is specified separately. Configure pressure range and electrical connection.

Digital meter/controller for AMETEK submersible level transmitters — a fully calibrated, microprocessor-based display with relays and optional analog retransmission. 110/220 VAC or 12/24 VDC input; display-only or two/four relays; optional 4–20 mA analog output; panel-mount or NEMA 4X weathertight housing; and optional lightning/surge protection on the signal and power lines. The engineering units shown and the paired transmitter model are specified at order. Configure power input, output, housing, and lightning protection.

Low-cost submersible level transducer for OEM and general level measurement. Wide choice of 4–20 mA or VDC outputs (including ratiometric), ranges 0–1 to 0–150 PSI, 316L stainless steel diaphragm, a Delrin or stainless snubnose, and vented polyurethane, polyolefin, or Teflon cable with a Viton seal. Optional on-board temperature output. Cable length is specified separately. Configure sensing port, output, range, electrical connection, and temperature option.

Slim-line submersible level transmitter — a narrow 0.75 in body for 1 in wells, piezometers, and tight boreholes. 11–30 VDC / 4–20 mA output, ranges 0–15 to 0–150 PSI (to ~346 ft of water), 316L stainless steel diaphragm, Delrin snubnose, and vented polyurethane cable with a Viton grommet. Cable length is specified separately. Select the pressure range; the remaining configuration is standard.

Modular electronic DP system that computes differential pressure from two absolute-pressure sensing modules — an alternative to remote-seal capillary systems for level in pressure tanks. 4-20 mA + HART, 0.1% accuracy, field-replaceable modules.

Industrial float level switch with reliable magnetic switching, horizontal or vertical mounting, and flanged connections 92x92 or DN80/ANSI 3 in. Full stainless option, IP66/IP68, DNV/BV/PRS maritime and ATEX certificates.

Bilge level switch designed for dirty liquids, in full 316L stainless steel with IP68 protection. Options include protective casing and test devices; DNV and PRS maritime certificates.

Compact float level switch with small in-tank dimensions and 92x92 flanged mounting (G2 or 2 NPT threaded on request). Full stainless and IP66/IP68 options; DNV/PRS maritime and ATEX explosion proof certificates.

Magnetic float level switch with one, two, or three signaling points and IP68 protection as standard. Float protection tube and custom designs to order; DNV/PRS maritime and ATEX certificates.

Electromagnetic flowmeter for conductive liquids, DN10 to DN1000 (ANSI 0.5 to 40 in), 0.5% accuracy (0.2% option). 4-20 mA, pulse/frequency outputs, Modbus RTU/RS485, wireless setup via smartphone; version for installation without straight run sections.

Compact electromagnetic flowmeter for conductive liquids, DN10 to DN300 (ANSI 0.5 to 12 in), 0.5% accuracy, static pressure to 4 MPa. 4-20 mA, pulse or frequency output, Modbus RTU/RS485; no-straight-run version available.

Averaging Pitot tube flow sensor with long-term accuracy, low permanent pressure loss, short straight-run requirements, and bi-directional measurement. Pairs with Aplisens differential pressure transmitters.

Smart hydrostatic level probe with Modbus RTU digital output for telemetry and PLC systems. 0.16% accuracy, programmable zero, range, and damping, ATEX/IECEx intrinsic safety certificate.

Smart hydrostatic level probe with 4-20 mA + HART, 0.1% accuracy, and programmable zero, range, and damping. Integrated overvoltage protection, ATEX intrinsic safety, DNV marine certificate; SGE-25C.Smart version with Hastelloy casing.

Hydrostatic level probe with all wetted parts in Hastelloy for seawater, brines, and aggressive media. Any measurement range, integrated overvoltage protection, ATEX intrinsic safety, DNV marine certificate.

Non-contact FMCW radar level transmitter using 80 GHz technology, with 4-20 mA output and compact IP68 housing. Also measures flow in open channels; configured via smartphone or tablet.

DP-flow primary elements — orifice plates, flow nozzles, micro-orifices, and monolithic meter runs — DN10 to DN1000, PN6 to PN100, calculated per PN-EN ISO 5167 with full documentation. Aplisens engineers size each element and can supply a complete set with DP transmitter and fittings.