9 product families(9 total products)

Electromagnetic flowmeter for conductive liquids, DN10 to DN1000 (ANSI 0.5 to 40 in), 0.5% accuracy (0.2% option). 4-20 mA, pulse/frequency outputs, Modbus RTU/RS485, wireless setup via smartphone; version for installation without straight run sections.

Compact electromagnetic flowmeter for conductive liquids, DN10 to DN300 (ANSI 0.5 to 12 in), 0.5% accuracy, static pressure to 4 MPa. 4-20 mA, pulse or frequency output, Modbus RTU/RS485; no-straight-run version available.

Flanged-body magnetic flow meter sensor — workhorse Rosemount mag flow primary element. All-welded sensor body for long-life pressure containment. Wide line-size range (½ to 36 inches) and full flange-rating coverage (ANSI 150# / 300# / 600#, EN equivalents). Lining options for almost any process: PTFE for chemicals, ETFE for high-temperature, Polyurethane for abrasive slurries, Neoprene for water/wastewater, Linatex for severe abrasion. Electrode materials from 316 SST workhorse to Hastelloy / Tantalum / Platinum / Titanium for corrosion-critical service. Pairs with the Rosemount 8712EM transmitter for the standard mag-flow installation.

Wafer-body magnetic flow meter sensor — same all-welded mag-flow architecture as the Rosemount 8705 but in a compact wafer body. Sandwiches between the customer's existing flanges (no integral flanges on the meter), reducing weight and cost vs flanged 8705. Best for line sizes ½ to 8 inches. Same liner / electrode / pairing options as 8705. Pairs with the Rosemount 8712EM transmitter.

Mag-flow transmitter electronics — pairs with any Rosemount 8705 / 8711 / 8750W mag-flow sensor. Intuitive Local Operator Interface (LOI) with dedicated keys for instant access to common parameters. HART 4-20 mA output (workhorse), FOUNDATION Fieldbus and PROFIBUS PA also available. Wall, pipe, or panel mount. Wide hazardous-area cert matrix (FM, CSA, ATEX, IECEx — both IS and XP variants). 90-250 VAC or 12-42 VDC supply. Smart Meter Verification (SMV) diagnostic confirms sensor health without removing from service.

Wall- or pipe-mount transmitter for the 8705/8711 magnetic flowmeter sensors. Provides 4-20 mA HART, FOUNDATION Fieldbus, or pulse output. Backlit LCD with local operator interface. Replaces sensor-integral transmitters when the meter must be installed away from the process for maintenance access.

Magnetic flow meter for general-purpose, utility, water, and wastewater service. Flanged sensor in line sizes 1/2 to 24 in., with an all-welded coil housing. Integral field-mount, remote field-mount, or remote wall-mount transmitter with a pulse output plus 4-20 mA HART, FOUNDATION Fieldbus, or Modbus RS-485. Polyurethane, neoprene, or PTFE lining with 316L or nickel alloy C-276 electrodes. Options include NSF drinking water certification on PTFE or polyurethane linings, grounding rings, and meter verification diagnostics.

Specialty mag-flow transmitter electronics tuned for slurry applications — mining, mineral processing, paper pulp, dredging, and any service where the process noise from suspended solids would overwhelm a standard mag-flow signal. Combines high-frequency dual-coil drive with proprietary noise-rejection algorithms (peak-to-peak signal averaging, automatic noise-burst rejection). Pairs with the Rosemount MS Magnetic Slurry Sensor for a complete slurry-rated assembly. HART or FOUNDATION Fieldbus output. The slurry industry workhorse where 8712EM + 8705 would lose lock.

Specialty mag-flow sensor purpose-built for slurry service. Heavy-duty electrode mounting + high-resistance liner combinations (Polyurethane, Neoprene, Linatex) deliver the wear life that pulp/paper, mining, mineral processing, and dredging require. Pairs with the Rosemount 8782 Slurry Transmitter for complete signal-noise rejection. Full flanged ANSI / DIN coverage from 1 in to 48 in. The slurry-industry workhorse alternative to the 8705/8711 standard sensors.