One of the best features of this RTD sensor is that it conforms to the standard 385 curve, letting you use your DIN/IEC RTD meters fully. Why use a precision thermometer or RTD temperature probe that’s less accurate than your meter?
The 5627A is manufactured using a coil suspension element design for increased shock and vibration resistance. It has a mineral-insulated sheath with a minimum bend radius of 19 mm (3/4-inch) for flexibility and durability. (Bend, if any, should be specified at time of order.)
Six- and nine-inch 5627A precision thermometers are calibrated at –196 °C, –38 °C, 0 °C, 200 °C, and 300 °C. For 12-inch versions of these precision thermometers, the point at 300 °C is replaced by a calibration point at 420 °C.
Key Features
- Temperature range up to 420 °C.
- Accuracy of up to ± 0.025 °C.
- NVLAP-accredited calibration.
- Three different length options, with both six- and nine-inch models covering a temperature range of -200 °C to 300 °C.
The Fluke Calibration Precision Industrial PRT, 12 in, Mini Banana Plugs # 5627A-12-M is manufactured by Fluke Calibration. Valley Instrument Service is an authorized Fluke Calibration dealer offering full sales support, NIST-traceable calibration, and expert technical assistance.
Have questions about this product?
Our team can help with product selection, specs, pricing, and application support.
Contact Us or Call (661) 327-8681| Resistance | Nominal 100 Ω |
| Temperature Coefficient | 0.00385 Ω/Ω/ °C nominal |
| Temperature Range | −200 °C to 420 °C (5627A-6 and 5627A-9 to 300 °C; transition and cable temperature: 0 °C to 150 °C) |
| Drift Rate (k=2) | ± 0.04 °C at 0 °C after 100 hours at 420 °C |
| Sheath Material | 316 Stainless Steel |
| Leads | PTFE-insulated, nickel-plated stranded copper, 22 AWG |
| Termination | Specify. See Ordering Information. |
| Time Constant | Four seconds maximum for 63.2 % response to step change in water moving at 3 fps. |
| Bending Radius | Sheath may be ordered with a bend on a minimum radius of 19 mm (3/4 in) except for 50 mm (2 in) area of sheath near tip. (Fluke lab requires 20 cm [8 in] of unbent sheath to re-calibrate.) |
| Calibration | Includes manufacturer's accredited calibration and table with R vs. T values in 1 °C increments from -196 °C to 500 °C (to 300 °C for 5627A-6 and 5627A-9).; ITS-90 coefficients included. |
| Immersion | At least 100 mm (4 in) recommended |
| Calibrated Accuracy† (k=2) | ± 0.026 °C at -196 °C; ± 0.046 °C at 0 °C; ± 0.077 °C at 200 °C; ± 0.124 °C at 420 °C |
| Size | 5627A-12: 305 mm x 6.35 mm (12 in x 1/4 in); 5627A-9: 229 mm x 4.7 mm (9 in x 3/16 in); 5627A-6: 152 mm x 4.7 mm (6 in x 3/16 in) |
This product is part of a family with 21 models. Select a model below to view details.
| Model | Price | |
|---|---|---|
5627A-6-P | Request Quote | View Details → |
5627A-6-M | Request Quote | View Details → |
5627A-6-L | Request Quote | View Details → |
5627A-6-J | Request Quote | View Details → |
5627A-6-D | Request Quote | View Details → |
5627A-6-B | Request Quote | View Details → |
5627A-6-A | Request Quote | View Details → |
5627A-9-P | Request Quote | View Details → |
5627A-9-M | Request Quote | View Details → |
5627A-9-L | Request Quote | View Details → |
Related Products

Fast Response PRT, 0.5 mm dia, 5-Pin DIN
Fast Response PRT, 0.5 mm dia, 5-Pin DIN termination, For 1502A / 1504 Tweener thermometer readouts

1502A Tweener Thermometer Readout, 115 V
Thermometer, Tweener, 110V 50/60HZ

1504 Tweener Thermistor Readout, 115 V
Thermometer, Thermistor, 110V 50/60HZ

4180 Precision IR Calibrator, 152 mm (6 in) Target, -15 to 120 °C, 115 V
Precision Infrared Calibrator, 152 mm (6 in) target, -15 to 120 °C, 115 V