Fluke 1552A Stik Thermometer is the "gold standard" of industrial temperature calibration
Finally, there is a digital substitute for your mercury-in-glass thermometers. The Fluke 1552A "Stik" Thermometer delivers repeatable temperature measurements accurate to ±0.05°C over its full range.
Whether you work outdoors in environments where potentially explosive gases may be present or on the floor of a processing plant, the intrinsically-safe, battery operated, portable reference thermometer is designed to go where you work. It's a great choice for daily checks of working thermometers, custody transfer temperature determination, PET calibration, LIG calibration, and temperature transmitter calibration and verification.
Included
- Fixed PRT, -80°C to 300°C
- NVLAP-accredited report of calibration
- User’s Guide on CD-ROM
- 3 AAA batteries
Key Features
- Intrinsically-safe, battery operated, portable reference thermometer
- Provides accuracy of ±0.05°C (±0.09°F) over full range
- Features intrinsically-safe operation (ATEX and IECEx compliant)
- Measures -80 °C to 300 °C ( -112 °F to 572 °F)
- Provides user-configurable temperature with Trend/Stability indicator
- Displays temperature in °C or °F
The Fluke Calibration Thermometer, Fixed PRT, -80 to 300C, 1/4x12 # 1552A-12 is manufactured by Fluke Calibration. Valley Instrument Service is an authorized Fluke Calibration dealer offering full sales support, NIST-traceable calibration, and expert technical assistance.
Have questions about this product?
Our team can help with product selection, specs, pricing, and application support.
Contact Us or Call (661) 327-8681| Temperature range | -80°C to 300°C; (-112°F to 572°F) |
| Accuracy (1 year) | ±0.05°C (±0.09°F) |
| Temperature resolution | Selectable: 0.1, 0.01, 0.001 (default 0.01) |
| Sample rate | Selectable: 0.5 seconds, 1 second, 2 seconds (default 1 second) |
| Readout temperature coefficient | Add ±10 ppm/°C of full scale temperature from −10 °C to 18 °C and 28 °C to 50 °C |
| Probe temperature coefficient | 0.00385 Ω/Ω/°C nominal |
| Nominal probe resistance at 0 °C | 100 Ω |
| Probe hysteresis | ±0.01°C |
| Response time | Approximately 20 seconds |
| Operating temperature range of readout | -10°C to 50°C (14°F to 122°F) |
| Humidity range | 0% to 95% RH, non-condensing |
| Storage temperature | -20°C to 60°C (-4°F to 140°F) |
| Display units | °C, °F |
| Sensor type | 100 Ω wire-wound PRT |
| Sensor length | ≤ 30 mm |
| Sensor position (from sheath tip) | 3 mm (0.1 in) |
| Minimum immersion depth | Wet medium (liquid bath, thermowell with thermal compound) 70 mm (2.8 in); Dry medium (dry-well, thermowell without thermal compound) 120 mm (4.8 in) |
| Maximum immersion depth | 75 mm (3 in) less than the total length. Make sure the last 75 mm of the probe, nearest to the internal electronics of the device, are not put into the heat source. |
| Probe sheath material | Stainless steel |
| Optional data logging 1 | Up to 10,000 time-stamped readings stored to internal memory |
| Logging intervals 1 | 2 seconds, 5 seconds, 10 seconds, 30 seconds, or 60 seconds |
| Damping | Moving average of the most recent 2 to 10 readings; (ON/OFF, 2, 5, 10) |
| Communications | RS-232 stereo jack (access calibration parameters only) |
| AC power | None |
| DC power | 3-AAA alkaline batteries; See Users Manual for approved batteries |
| Battery life | Approximately 300 hours (12.5 days) of continuous operation with the backlight off. |
| Battery save (auto-off) range | Selectable from 1 to 30 minutes or can be disabled |
| Safety | IEC 60079-0, IEC 60079-11: Ex ib IIB T4 Gb; IEC 61010-1: Pollution Degree 2 |
| Electromagnetic compatibility | International:; IEC 61326-1: Portable Equipment;; IEC 61326-2-2; CISPR 11: Group 1, Class B; Group 1: Equipment has intentionally generated and/or uses conductively coupled radio frequency energy that is necessary for the internal function of the equipment itself.; Class B: Equipment is suitable for use in domestic establishments and in establishments directly connected to a low voltage power supply network which supplies buildings used for domestic purposes.; USA (FCC):; 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. |
| Size (readout only) | 125 mm x 62 mm x 35 mm (5 in x 2.5 in x 1.4 in) |
| Probe Size | 6.35 mm x 305 mm (1/4 in x 12 in) |
| Weight | 200 g (6.9 oz) |
| Calibration (included) | accredited, NIST-traceable |
| Characterization | ITS-90 |
This product is part of a family with 2 models. Select a model below to view details.
| Model | Price | |
|---|---|---|
1552A-12Current | Request Quote | Viewing |
1552A-12-DL | Request Quote | View Details → |
Related Products

1502A Tweener Thermometer Readout, 115 V
Thermometer, Tweener, 110V 50/60HZ

1504 Tweener Thermistor Readout, 115 V
Thermometer, Thermistor, 110V 50/60HZ
Bundle, 1524 w/Case, 5615-12-P, LEMO to TC Adapter
Bundle, 1524 w/Case, 5615-12-P, LEMO to TC Adapter
Cable, RS-232, 155X
Cable, RS-232, 155X