The Chub-E4 has four inputs for reading four different sensors simultaneously, and we’ll configure those inputs in any of three different ways according to your preference. Choose four channels of thermocouple inputs, four channels of PRT/thermistor inputs, or two channels of each. With this thermometer, reading thermocouples, PRTs, and thermistors accurately from the same device is no problem.
100-ohm, 25-ohm, or 10-ohm PRTs and RTDs are read using ITS-90, IEC-751 (DIN), or Callendar-Van Dusen conversion methods. Typical accuracies include ±0.004 °C at –100 °C and ±0.009 °C at 100 °C. Thermistor readings are converted using the Steinhart-Hart polynomial or standard YSI-400 curve and are as accurate as ±0.0025 °C at 25 °C with resolution of 0.0001 °.
Thermocouple inputs read all the common thermocouple types, including B, E, J, K, N, R, S, T, and Au-Pt, and allow you to choose between internal and external reference junction compensation. Typical accuracy for a type J thermocouple at 600 °C is ±0.35 °C using internal reference junction compensation and not including the thermocouple. (Support for C and U type thermocouples is available. Download the application note Using Fluke Calibration Readouts with Tungsten-Rhenium and other Thermocouples.)
Key Features
- Supports four channels for PRTs, thermistors, and thermocouples, accommodating a variety of sensor types.
- Display eight user-selected data fields from any channel.
- Log up to 8,000 readings with date and time stamps for data tracking.
- Eight hours of continuous operation
The Fluke Calibration Thermometer, CHUB-E4,4-TC Inputs # 1529-T-156 is manufactured by Fluke Calibration. Valley Instrument Service is an authorized Fluke Calibration dealer offering full sales support, NIST-traceable calibration, and expert technical assistance.
Have questions about this product?
Our team can help with product selection, specs, pricing, and application support.
Contact Us or Call (661) 327-8681| Inputs | 2 channels PRT/thermistor and 2 channels TC, or 4 channels PRT/thermistor, or 4 channels TC, specify when ordering;; PRT/thermistor channels accept 2, 3, or 4 wires; TC inputs accept B, E, J, K, N, R, S, T, and Au-Pt TC types. (Support for C and U type thermocouples is available. Download the application note Using Fluke Calibration Readouts with Tungsten-Rhenium and other Thermocouples) |
| Temperature Range | –189 °C to 960 °C; –50 °C to 150 °C; –270 °C to 1800 °C |
| Measurement Range | 0 to 400 Ω; 0 to 500 KΩ; –10 to 100 mV |
| Characterizations | ITS-90, IEC-751 (DIN “385”), Callendar-Van Dusen; Steinhart-Hart, YSI-400; NIST Monograph 175, 3-point deviation function applied to NIST 175, 6th-order polynomial |
| Temperature Accuracy (meter only) | ± 0.004 °C at –100 °C; ± 0.006 °C at 0 °C; ± 0.009 °C at 100 °C; ± 0.012 °C at 200 °C; ± 0.018 °C at 400 °C; ± 0.024 °C at 600 °C; ± 0.0025 °C at 0 °C; ± 0.0025 °C at 25 °C; ± 0.004 °C at 50 °C; ± 0.010 °C at 75 °C; ± 0.025 °C at 100 °C; Ext. RJC Int. RJC; B at 1000 °C ± 0.6 °C ± 0.6 °C; E at 600 °C ± 0.07 °C ± 0.25 °C; J at 600 °C ± 0.1 °C ± 0.35 °C; K at 600 °C ± 0.15 °C ± 0.4 °C; N at 600 °C ± 0.15 °C ± 0.3 °C; R at 1000 °C ± 0.4 °C ± 0.5 °C; S at 1000 °C ± 0.5 °C ± 0.6 °C; T at 200 °C ± 0.1 °C ± 0.3 °C |
| Temperature Resolution | 0.001 °; 0.0001 °; 0.01 to 0.001 ° |
| Resistance/Voltage Accuracy | 0 Ω to 20 Ω: ± 0.0005Ω; 20 Ω to 400 Ω: ± 25 ppm of rdg.; 0 Ω to 5 KΩ: ± 0.5 Ω; 5 KΩ to 200 KΩ: ± 100 ppm of rdg.; 200 KΩ to 500 KΩ ± 300 ppm of rdg.; –10 to 50 mV: ± 0.005 mV; 50 to 100 mV: ± 100 ppm of rdg.; Internal RJC: ± 0.25 °C) |
| Operating Range | 16 °C to 30 °C |
| Measurement Interval | 0.1 second to 1 hour; inputs may be read sequentially or simultaneously at 1 second or greater interval |
| Excitation Current | 1 mA, reversing; 2 and 10 µA, automatically selected; n/a |
| Display | 33 x 127 mm (1.3 x 5 in) backlit LCD graphical display |
| Display Units | °C, °F, K, Ω, KΩ, mV |
| Data Logging | Up to 8,000 time- and date-stamped measurements can be logged |
| Logging Intervals | 0.1, 0.2, 0.5, 1, 2, 5, 10, 30, or 60 seconds; 2, 5, 10, 30, or 60 minutes |
| Averaging | Moving average of most recent 2 to 10 readings, user selectable |
| Probe Connection | Patented DWF Connectors accept mini spade lug, bare-wire, or mini banana plug terminations; Universal receptacle accepts miniature and standard TC connectors |
| Communications | RS-232 included, IEEE-488 (GPIB) optional |
| AC Power | 100–240 V ac, 50-60 Hz, 0.4 A |
| DC Power | 12–16 VDC, 0.5 A (battery charges during operation from 14.5 to 16V DC, 1.0A) |
| Battery | NiMH, 8 hours of operation typical without backlight, 3 hours to charge, 500 cycles |
| Size (HxWxD) | 102 x 191 x 208 mm (4.0 x 7.5 x 8.2 in) |
| Weight | 2 kg (4.5 lb) |
| Calibration | Accredited resistance and voltage calibrations are provided. |
This product is part of a family with 3 models. Select a model below to view details.
| Model | Price | |
|---|---|---|
1529-156 | Request Quote | View Details → |
1529-R-156 | Request Quote | View Details → |
1529-T-156Current | Request Quote | Viewing |