Product Image
You need accuracy for compliance, product yields, energy savings, and consistent results. The 1524 uses current reversal, a technique used in high-end instruments that eliminates thermal EMFs, for precision temperature measurements. Specifications are guaranteed from -10 °C to 60 °C ambient. Special precision resistors and a highly stable reference voltage source keep 1524 accuracy virtually insensitive to environmental temperature.
Like all Fluke handheld tools, the 1524 Reference Thermometers endure rigorous testing in temperature extremes and under harsh conditions of vibration, so you can take them anywhere you need to go.
An optional magnetic hanger allows you to hang the thermometer for easy viewing while freeing your hands to focus on the job.
This Model
Fluke Calibration 1524-P3 Handheld Thermometer Readout. 1524 Bundled with 5627A PRT
Included
- 5627A PRT
- Universal TC INFO-CON Connector
- TPAK
- Case
Key Features
- Measure, graph, and record PRTs, thermocouples, and thermistors, supporting a wide range of temperature sensors.
- Accuracy up to ±0.002 °C.
- Quick sample readings in as little as 0.3 seconds.
- 1524 has two channels for simultaneous measurements, doubling productivity.
The Fluke Calibration Bundle, 1524 w/Case, 5627A, LEMO to TC Adapter # 1524-P3-156 is manufactured by Fluke Calibration. Valley Instrument Service is an authorized Fluke Calibration dealer offering full sales support, NIST-traceable calibration, and expert technical assistance.
Have questions about this product?
Our team can help with product selection, specs, pricing, and application support.
Contact Us or Call (661) 327-8681| Input channels | 2 |
| Logging | 15,000 time and date stamped; 25 readings with statistics |
| Sample interval; (normal) | 1 second |
| Sample interval (fast mode) | 0.3 seconds (see technical manual for details) |
| Sensor types | PRTs, RTDs, thermistors, and thermocouples |
| Thermocouple types | C, E, J, K, L, M, N, T, U, B, R, S |
| Operating temperature | -10°C to 60°C (Best accuracy 13°C to 33°C) |
| Power requirements | 3 AA alkaline batteries |
| Size | 96 x 200 x 47 mm; (3.75 x 7.9 x 1.86 in) |
| Weight | 0.65 kg (1.4 lb) |
| Environmental conditions for best accuracy | 13°C to 33°C |
| Millivolt range and accuracy | –10 mV to 75 mV ±(0.005% + 5 μV) |
| Resistance range and accuracy | 0 Ω to 400 Ω ±(0.004% + 0.002 Ω); 200 Ω to 50 kΩ ±(0.01% + 0.5 Ω); 50 kΩ to 500 kΩ ± (0.03%) |
| Temperature coefficient, voltage (–10°C to 13°C, +33°C to 60°C) | ±(0.001%/°C + 1 μV/°C) |
| Temperature coefficient, resistance (–10°C to 13°C, +33°C to 60°C) | 0.0008%/°C + 0.0004 Ω (0 Ω to 400 Ω); 0.002%/°C + 0.1 Ω (0 Ω to 50 kΩ); 0.06%/°C + 0.1 Ω (50 kΩ to 500 kΩ) |
| Excitation current, resistance | 1 mA (0 Ω to 400 Ω); 10 μA (0 Ω to 50 kΩ); 2 µA (50 kΩ to 500 kΩ) |
| Type B | ±0.85°C from 600°C to 800°C; ±0.68°C from 800°C to 1000°C; ±0.57°C from 1000°C to 1800°C |
| Type C | ±0.32°C from 100ºC to 550°C; ±0.71°C from 550°C to 2300°C |
| Type E | ±0.52°C from -200°C to 0°C; ±0.22°C from 0°C to 950°C |
| Type J | ±0.52°C from -200°C to 0°C; ±0.23°C from 0°C to 1200°C |
| Type K | ±0.61°C from -200°C to 0°C; ±0.24°C from 0°C to 1370°C |
| Type L | ±0.36°C from -200°C to 0°C; ±0.23°C from 0°C to 1370°C |
| Type M | ±0.26°C from -20°C to 0°C; ±0.25°C from 0°C to 400°C; ±0.22°C from 400°C to 1400°C |
| Type N | ±0.72°C from -200°C to 0°C; ±0.28°C from 0°C to 1300°C |
| Type R | ±1.09°C from -20°C to 0°C; ±0.97°C from 0°C to 500°C; ±0.49°C from 500°C to 1750°C |
| Type S | ±1.05°C from -20°C to 0°C; ±0.95°C from 0°C to 500°C; ±0.56°C from 500°C to 1750°C |
| Type T | ±0.60°C from -200°C to 0°C; ±0.25°C from 0°C to 400°C |
| Type U | ±0.54°C from -200°C to 0°C; ±0.24°C from 0°C to 400°C |
| -200°C | 5616-12: 0.014; 5615-6: 0.025; 5627A-12: 0.027; 5610-9: n/a |
| 0°C | 5616-12: 0.021; 5615-6: 0.021; 5627A-12: 0.049; 5610-9: 0.009 |
| 100°C | 5616-12: 0.027; 5615-6: 0.028; 5627A-12: 0.065; 5610-9: 0.009 |
| 300°C | 5616-12: 0.040; 5615-6: 0.043; 5627A-12: 0.103; 5610-9: n/a |
| 420°C | 5616-12: 0.050; 5615-6: n/a; 5627A-12: 0.130; 5610-9: n/a |
| –100°C | ±0.011 |
| 0°C | ±0.015 |
| 100°C | ±0.019 |
| 200°C | ±0.023 |
| 400°C | ±0.031 |
| 600°C | ±0.039 |
| 0°C | ±0.002 |
| 25°C | ±0.003 |
| 50°C | ±0.006 |
| 75°C | ±0.014 |
| 100°C | ±0.030 |
Accessories, replacement sensors, and parts for this product family.
| Model | Price | |
|---|---|---|
1524-P3-156Current | Request Quote | Viewing |
1524-P4-156 | Request Quote | View Details → |
1524-P4-256 | Request Quote | View Details → |
1524-P2-156 | Request Quote | View Details → |
Related Products

1502A Tweener Thermometer Readout, 115 V
Thermometer, Tweener, 110V 50/60HZ

1504 Tweener Thermistor Readout, 115 V
Thermometer, Thermistor, 110V 50/60HZ
Cable, RS-232, 155X
Cable, RS-232, 155X
Case, 1523/1524 Readout and Probe Carrying
Case, 1523/1524 Readout and Probe Carrying