2 GHz DSX Multimode OLTS Inspc V2, w/Wi-fi
DSX CableAnalyzer Series Copper Cable Certifiers
Key Features
- Versiv modular design supports copper certification, fiber optic loss, OTDR testing and fiber end-face inspection
- Unmatched speed for Cat 6A, 8, Class FA, I/II and all current standards
- ProjX system manages job requirements and progress from set-up to systems acceptance, making sure all tests are completed correctly
- Taptive user interface simplifies set-up, and eliminates errors
- Analyze test results and create professional test reports using LinkWare management software View More >
Software and firmware note: Versiv2 firmware 7.2 (October 2026) requires LinkWare PC 12.1 Build 14 or later. Firmware 7 and later is not compatible with original Versiv (V1) mains and remotes, Versiv TFS mains, or the DSX-600, whose final firmware release is 6.14 Build 9. If your team pairs this tester with any of those units, do not update past 6.14. Ask us before updating and we will confirm the right firmware for your kit.
The Fluke Networks 2 GHz DSX Multimode OLTS Inspc V2, with Wi-Fi DSX2-8000MI is manufactured by Fluke Networks. Valley Instrument Service is an authorized Fluke Networks dealer offering full sales support, NIST-traceable calibration, and expert technical assistance.
Have questions about this product?
Our team can help with product selection, specs, pricing, and application support.
Contact Us or Call (661) 327-8681| Shielded and unshielded pair LAN cabling | TIA Category 3, 4, 5, 5e, 6, 6A, 8: 100 Ω ISO/IEC Class C, D, E, EA, F, FA and I/II: 100 Ω and 120 Ω |
| Permanent link adapters | Plug type: shielded RJ45 Optional Plug type: Tera |
| Channel Adapters | Jack type: shielded RJ45 Optional Jack type: Tera, GG45 |
| TIA | Category 3, 4, 5, 5e, 6, 6A, 8 per ANSI/TIA-568.2-D |
| ISO/IEC | Class C and D, E, EA, F, FA and I/II certification per ISO/IEC |
| Maximum frequency | DSX-8000: 2000 MHz; DSX-5000: 1000 MHz |
| Speed of Autotest | DSX-8000: Full 2-way Autotest of Category 5e or 6/Class D or E: 7 seconds. Full 2-way Autotest of Category 6A/Class EA: 8 seconds. Full 2-way Autotest of Category 8: 16 seconds DSX-5000: Full 2-way Autotest of Category 5e or 6/Class D or E: 9 seconds. Full 2-way Autotest of Category 6A/Class EA: 10 seconds |
| Input protection | Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage |
| Display | 5.7 in LCD display with a projected capacitance touchscreen |
| Case | High impact plastic with shock absorbing overmold |
| Dimensions | Main Versiv unit with DSX module and battery installed: 2.625 in x 5.25 in x 11.0 in (6.67 cm x 13.33 cm x 27.94 cm) |
| Weight | Main Versiv unit with DSX module and battery installed: 3 lbs, 5oz (1.28 kg) |
| Main unit and remote: | Lithium ion battery pack, 7.2 V |
| Typical battery life: | 8 hours |
| Charge time* | Tester off: 4 hours to charge from 10 % capacity to 90 % capacity. |
| Languages supported | English, French, German, Italian, Japanese, Portuguese, Spanish, Chinese, Korean, Russian, Trad Chinese, Czech, Polish, Swedish, Hungarian |
| Calibration | Service center calibration period is 1 year |
| Integrated Wi-Fi | Meets IEEE 802.11 a/b/g/n; dual band (2.4 GHz and 5 GHz) |
| Operating Temperature | 32°F to 113°F (0°C to 45°C) |
| Storage Temperature | -14°F to +140°F (-10°C to +60°C) |
| Operating relative humidity | 0 % to 90 %, 32°F to 95 °F (0°C to 35°C) 0 % to 70 %, 95°F to 113 °F (35°C to 45°C) |
| Vibration | Random, 2 g, 5 Hz-500 Hz |
| Shock | 1 m drop test with and without module and adapter |
| Safety | CSA 22.2 No. 61010, IEC 61010-1 3rd Edition |
| Operating altitude | 13,123 ft (4,000 m) 10,500 ft (3,200 m) with ac adapter |
| EMC | EN 61326-1 |
| DSX-8000 | Category 8 test modes (or lower link categories) Class I/II test modes |
| DSX-5000 | Category 6A/Class EA test modes (or lower link categories) Class FA test modes |
| Length of Twisted Pair Cabling1 | Without Remote or in DSX-5000 Long Communication Mode |
| Range | 800 m (2600 ft) |
| Resolution | 0.1 m or 1 ft |
| Accuracy | ± (0.3 m + 2 %); 0 m to 150 m ± (0.3 m + 4 %); 150 m to 800 m |
| Propagation Delay | Without Remote or in DSX-5000 Long Communication Mode |
| Range | 4000 ns |
| Resolution | 1 ns |
| Accuracy | ± (2 ns + 2 %); 0 ns to 750 ns ± (2 ns + 4 %); 750 ns to 4000 ns |
| Range | 0 ns to 100 ns |
| Accuracy | ± 10 ns |
| Range | 0 Ω to 540 Ω |
| Resolution | 0.1 Ω |
| Accuracy | ± (1 Ω + 1 %) |
| Overload recovery time | Less than 10 minutes to rated accuracy following an overvoltage. Referencing is required after repeated or prolonged overvoltage. |
Related Products

1 GHz DSX Quad OLTS Insp V2, with Wi-Fi
Versiv mainframe and remote • 2 DSX-5000 CableAnalyzer modules • 2 CertiFiber Quad OLTS modules • USB video inspection probe • Wi-Fi

1 GHz DSX-5000 and Quad OLTS Modules Add-on Kit with V2 Remote
1 GHz DSX-5000 and Quad OLTS Modules Add on Kit w/V2 Remote

2 GHz DSX and Quad OLTS Modules Add on Kit with V2 Remote
2 GHz DSX and Quad OLTS Modules Add on Kit w/V2 Remote
CFM Singlemode Main/Remote Output Adapter
CFM Sm Main/Remote Output Adapter