Fluke 724 handheld temperature calibrator. Sources and measures thermocouples (J, K, T, E, R, S, B, L, U, N, C, XK, BP), RTDs (Pt100/200/500/1000, Ni120, Cu10), mA, volts, ohms, and frequency from a single tool. Dual display measures the TC or RTD input while simultaneously sourcing mA, so a transmitter can be verified in one pass — source the process variable, read the loop current. Suited to process plants, power generation, and instrumentation shops calibrating temperature transmitters, thermostats, and indicators in the field.
Fluke 724 temperature calibrator: test & calibrate almost any temperature instrument. Switch from RTDs to TCs, source & measure, troubleshoot. Dual display.
Key Features
- Powerful, easy-to-use, high-accuracy temperature calibrator
- Test and calibrate temperature sensors and transmitters
- Measures 4 to 20 mA loops and can provide loop power
- Measures RTDs, thermocouples, ohms, and volts
- Source/simulates thermocouples, RTDs, volts, and ohms
The Fluke 724 Temperature Calibrator FLUKE-724 is manufactured by Fluke. Valley Instrument Service is an authorized Fluke dealer offering full sales support, NIST-traceable calibration, and expert technical assistance.
Have questions about this product?
Our team can help with product selection, specs, pricing, and application support.
Contact Us or Call (661) 327-8681| General | Measurement Accuracy |
| 30.000 V | 0.02% + 2 counts (upper display) |
| 20.000 V | 0.02% + 2 counts (lower display) |
| 100.00 mV | 0.02% + 2 counts |
| -10.00 mV to 75.00 mV | 0.025% + 1 count (via TC connector) |
| Current DC | 24.000 mA |
| 0.0 to 400.0 Ω | 0.1 Ω (4-wire), 0.15 Ω (2- and 3-wire) |
| 401 to 1500 Ω | 0.5 Ω (4-wire), 1 Ω (2- and 3-wire) |
| 1500 to 3200 Ω | 1 Ω (4-wire), 1.5 Ω (2- and 3-wire) |
| Resistance | Source Accuracy |
| 10.000 V | 0.02% + 2 counts |
| 15.0 to 400.0 Ω | 0.15 Ω (exc. current 0.15 to 0.5 mA), 0.1 Ω (exc. current 0.5 to 2 mA) |
| NI-120 | 0.2°C |
| PT-100 (385) | 0.33°C |
| PT-100 (393) | 0.3°C |
| PT-100 (JIS) | 0.3°C |
| PT-200 (385) | 0.2°C |
| PT-500 (385) | 0.3°C |
| PT-1000 (385) | 0.2°C |
| Resolution | 0.1°C |
| J | 0.7°C |
| K | 0.8°C |
| T | 0.8°C |
| E | 0.7°C |
| R | 1.8°C |
| S | 1.5°C |
| B | 1.4°C |
| L | 0.7°C |
| U | 0.75°C |
| N | 0.9°C |
| XK | 0.6°C |
| BP | 1.2°C |
| Source accuracy | Accuracy stated for 4-wire measurement. |
| Source functions | Voltage, current, resistance, frequency, temperature |
| Ramps | Slow ramp, Fast ramp, 25% step-ramp |
| Voltage | 24 V |
| Accuracy | 10% |
| Maximum current | 22 mA, short circuit protected |
| Steps | 25% of range, 100% of range |
| Step functions | Environmental Specifications |
| Operating temperature | -10°C to 55°C |
| Storage temperature | -20°C to 71°C |
| 90% | 10°C to 30°C |
| 75% | 30°C to 40°C |
| 45% | 40°C to 50°C |
| 35% | 50°C to 55°C |
| Humidity (without condensation) | Safety Specifications |
| Safety rating | CSA C22.2 No. 1010.1:1992 |
| EMC | EN50082-1:1992 and EN55022:1994 Class B |
| Size | 96 x 200 x 47 mm |
| Weight | 650 g |
| Batteries | Four AA alkaline batteries |
| Warranty | Three years |
| Battery life | 25 hours typical |
| Shock and vibration | Random, 2 G, 5-500 Hz |
Related Products

712B/EN RTD Calibrator
Fluke 712B Handheld RTD Calibrator provides highly accurate, easy-to-use, single-function RTD temperature calibration. Measure & simulate 13 RTD types.

714B/EN Thermocouple Calibrator
The Fluke Calibration 714B thermocouple calibrator measures and simulates 9 types of thermocouples, providing durable and reliable performance for process calibration.

789 and 773 Bundle Package
Fluke 789 ProcessMeter is wireless via Fluke Connect & combines a DMM & loop calibrator. Large, bright dual display. Get specs and buy official Fluke here.

154 US/CAN HART Calibration Assistant, US, Canada
The Fluke 154 HART Communicator is a standalone tablet based tool that wirelessly connects to the HART transmitter. See the specs or talk with an engineer.