The i310 current probe offered by Fluke can be used to measure both DC and AC current for accurate measurements. Contact us for more information.
Key Features
- Current Ranges: 30 A and 300 A ACRMS or ±45 A and 450 A DC
- Measuring Ranges: ±45 A and 450 A dc
- Output Sensitivity: 10 mV/A (40 A) to 1 mV/A (400 A)
- Resolution: ±50 mA (40 A) to ±100 mA (400 A)
- Load Impedance: > 10 k Ohms and £ 100 pF
- Frequency Range (small signal): DC to 20 kHz (- 3 dB)
- Phase Shift below 1 kHz,
- Temperature Coefficient: ±0.1% of reading / °C
- Power Supply: 9 V Alkaline
The Fluke i310S AC/DC Current Clamp # I310S is manufactured by Fluke. Valley Instrument Service is an authorized Fluke dealer offering full sales support, NIST-traceable calibration, and expert technical assistance.
Have questions about this product?
Our team can help with product selection, specs, pricing, and application support.
Contact Us or Call (661) 327-8681| General | Electrical Characteristics |
| Current ranges | 30 A and 300 A AC rms or ±45 A and 450 A DC |
| Measuring ranges | ±45 A and 450 A DC |
| AC rms or DC | ±45 A and 450 A |
| Inrush current | 600A AC rms MAX |
| Output sensitivity | 1 mV/A (300 A) |
| (30 A range) | ±1% of reading ±50 mA |
| (300 A range) | ±1% of reading ±300 mA |
| Bandwidth to meet accuracy specification | 1 kHz |
| Phase shift below 1 kHz | < 2 degrees |
| Resolution | ±100 mA (300 A) |
| Load impedance | > 10 k Ohms and ≤100 pF |
| Conductor position sensitivity | ±1.5% relative to centre reading |
| Frequency range (small signal) | DC to 20 kHz (-3 dB) |
| Temperature coefficient | ±0.1% of reading / °C |
| Power supply | 9 V Alkaline, MN1604/PP3 |
| Battery life | 30 Hours, low battery indicator |
| Working voltage (see Safety Standards section) | 300 V AC rms or DC |
| Maximum conductor size | 19 mm diameter |
| Output connection | Supplied with safety 4mm adaptor |
| Output zero | Manual adjust via thumbwheel |
| Cable length | 2 metres |
| Operating temperature range | -10 to +50°C |
| Storage temperature range (with battery removed) | -20 to +85°C |
| Operating humidity | 15% to 85% (non-condensing) |
| Weight | 250 g |
| Safety | IEC 61010-2- 032: CAT III 300V |
| EMC Compatibility | IEC 61326-1: Portable Electromagnetic Environment |
Related Products

116/323 KIT HVAC Multimeter and Clamp Meter Combo Kit
Get the right HVAC multimeter for accurate temperature & microamp measurements. The Fluke 116 digital multimeter has everything you need in an HVAC meter.

17XX I40S-EL Clamp-on Current Transformer
The Fluke i40s-EL Current Clamp-on Transformer is used for low current measurement; suitable for making measurements up to 40A, and also measures accurately on 1A and 5A secondary current transformers.

2, 000A AC/DC Current Clamp /3PK
The 80I-110s is compatible with any Fluke ScopeMeter Test Tool, Power Harmonics Analyzer, Oscilloscope, Multimeter, or other voltage measurement device that has the following features: BNC input connectors or if using a meter convert the banana plugs to a BNC connector using the adapter PM9081/001.

301D-R 600A AC/DC Clamp Meter with Slim Body and Thin Jaw Arm Retail
The slim and thin jaw can easily fit into tightly packed wires. The lightweight and compact design allows you to carry it around in your pocket