Tank-gauging multi-input temperature transmitter — purpose-built for custody-transfer-grade tank temperature measurement. Integrates up to 16 Pt-100 RTD spot elements (Cu-90 also supported) over -200 to 250 °C, plus optional Rosemount 765 water-level sensor input. ±0.05 °C transmitter accuracy (excluding sensor error). Premium performance class, FOUNDATION Fieldbus / Tankbus 2-wire bus-powered output. Custody-transfer type approvals available for PTB (Germany), NMIM (Malaysia), and GOST (Kazakhstan) — requires pairing with a Rosemount 2410 Tank Hub and 5900S Radar Level Gauge of matching approval. Polyurethane-covered aluminum IP66/67 enclosure. Hazardous-area: Intrinsic Safety only (FM/CSA/ATEX/IECEx/INMETRO/NEPSI/TIIS/EAC/KCs).

Required Specifications

10 of 10 selected
1
Performance Class*

The 2240S is offered only in the Premium class. Tank-gauging applications demand ±0.05 °C accuracy.

P
2
Number of Temperature Sensor Inputs*

Up to 16 RTD spot elements (Pt-100 or Cu-90). Code 00 = no temperature spots (water-level-only mode, requires aux input A).

16
3
Temperature Elements Wiring*
4
4
Auxiliary Inputs*
A
5
Tankbus: Power and Communication*

The 2240S is fundamentally a tank-gauging device — Tankbus FOUNDATION Fieldbus is the only output.

F
6
Hazardous Location Certification*

All 2240S approvals are Intrinsic Safety — typical for Tankbus-powered field devices in tank-gauging service.

NA
7
Custody Transfer Type Approval*

Custody-transfer codes (C/J/K) reserve one spot position for an external reference — reduces available element count by 1 (e.g. selecting 16 + C yields 15 usable spots). Requires pairing with a Rosemount 2410 Tank Hub + 5900S Radar Level Gauge with matching approval, plus a display (2410 integral, 2230 display, or TankMaster).

C
8
Housing*

Standard polyurethane-covered aluminum IP66/67. Only option.

A
9
Cable / Conduit Connections*
1
10
Mechanical Installation*

M = ready to mount directly to a Rosemount 565, 566, or 765 sensor head (the typical Tank-Gauging assembly). W/P = installation kit for separate sensor + transmitter installation.

M

Configure your Rosemount 565 Multiple Spot Temperature Sensor

Ships factory-assembled to the transmitter above. Configured part number generated separately.

565 Required Specifications

9 of 9 selected
1
Overall Length (Lo)*

The tank-spanning length of the sensor. Metric range 2000-70000 mm (2-70 m) in 10 mm steps. US range 80-2700 in (≈6.7-225 ft) in 1 in steps. Custom length specified at quote.

M25000
2
Sheath Type*
A
3
Tank Connection*

ANSI raised-face flanges (A-L), EN flat-face flanges (1-7), or M33×1.5 threaded (code 0). All flanges in SST AISI 316.

0
4
Temperature Sensor Wiring*
4
5
Number of Temperature Spot Elements*

1-16 spot elements distributed along the sensor length. Tank-gauging applications typically use 6-16 elements for full vertical profile.

16
6
Element Type*
P
7
Thermometer Tolerance Class*

IEC 60751 spec. Class 1/10 (code 2) requires four-wire sensor wiring.

2
8
Thermometer Temperature Range*
2
9
Lead Wires*

Standard integrated installation with Rosemount 2240S transmitter is code 00. Specify a length code for remote-mount installations: 04-10 in meters, 13-33 in feet.

00

Configure your Rosemount 765 Multiple Spot Temperature + Water Level Sensor

Ships factory-assembled to the transmitter above. Configured part number generated separately.

765 Required Specifications

10 of 10 selected
1
Overall Length (Lo)*

PDS: 765 metric range 2000-60000 mm (2-60 m, 10 mm steps) — note SHORTER than 565/566. US range 80-2300 in (1 in steps).

M25000
2
Sheath Type*
A
3
Tank Connection*

PDS: ANSI raised-face flanges (A-L), EN flat-face flanges (1-7), or M33×1.5 threaded (code 0). All flanges in SST AISI 316. Crude oil / petroleum tanks typically use 4-in or 6-in Class 150 RF.

G
4
Temperature Sensor Wiring*

PDS spot-element limits: wiring 4 → max 10 spots; wiring 3 → max 14 spots; wiring C → max 16 spots. (Water-level-only mode wiring=0 not exposed here — contact for quote.)

4
5
Number of Temperature Spot Elements*

PDS: 01-16 spot elements distributed along the sensor length, with wiring-dependent maximums (see Sensor Wiring).

10
6
Element Type*
P
7
Thermometer Tolerance Class*

PDS: Class 1/10 (code 2) requires four-wire sensor wiring.

2
8
Thermometer Temperature Range*
1
9
Lead Wires*

Standard integrated installation with Rosemount 2240S transmitter is code 00. Specify a length code for remote-mount installations: 04-10 in meters, 13-33 in feet.

00
10
Water-Level Sensor*

PDS-real codes. Closed (C) for light products; open (H) for crude and heavy duty. Range is either 500 mm (19 in) or 1000 mm (39 in).

H05
Rosemount 2240S Multi-Input Temperature Transmitter Part Number
2240SP164AFNACA1M
Pricing:Contact Valley Instrument for a quote on this configuration
ROSEMOUNT-565 Part Number(incomplete: finish above)
0565
ROSEMOUNT-765 Part Number(incomplete: finish above)
0765
Configuration Summary: Rosemount 2240S Multi-Input Temperature Transmitter
Performance Class:
PP — Premium (±0.05 °C transmitter accuracy)price on request
Number of Temperature Sensor Inputs:
1616 — Up to 16 RTD spot elementsprice on request
Temperature Elements Wiring:
44 — 4-wire or 3-wire (individual or common return)price on request
Auxiliary Inputs:
AA — Rosemount 765 temperature + water-level sensor inputprice on request
Tankbus: Power and Communication:
FF — Bus-powered 2-wire FOUNDATION Fieldbus (IEC 61158)price on request
Hazardous Location Certification:
NANA — No hazardous-location certificationprice on request
Custody Transfer Type Approval:
CC — PTB (German W&M approval — one spot used for external reference)price on request
Housing:
AA — Standard enclosure (polyurethane-covered aluminum, IP66/67)price on request
Cable / Conduit Connections:
11 — ½-14 NPT, female (includes 2 plugs)price on request
Mechanical Installation:
MM — Prepared for integrated installation with Rosemount 565 / 566 / 765 (standard)price on request

Rosemount is configurator-heavy and quote-only. Valley Instrument verifies option compatibility, lead time, and pricing before confirming your order. Assembled configurations ship factory-built as a single unit.

Related Products

Rosemount 248 Head Mount Temperature Transmitter # 248
Rosemount

248 Head Mount Temperature Transmitter

Basic, cost-effective HART head-mount temperature transmitter for temperature monitoring points. DIN-B form factor mounts directly inside the sensor's connection head, eliminating the need for extension wires or multiplexers. Single-sensor 4-20 mA HART output, ±0.15 °C digital accuracy, with worldwide hazardous-area approvals (FM, CSA, ATEX, IECEx, NEPSI, EAC). Aluminum or stainless-steel enclosure options; sanitary DIN-A/DIN-B variants for hygienic process. Pairs with any standard 2-, 3-, or 4-wire RTD or thermocouple sensor.

Request Quote →
Rosemount 248R Rail Mount Temperature Transmitter # 248R
Rosemount

248R Rail Mount Temperature Transmitter

Compact DIN-rail-mount variant of the Rosemount 248 platform. HART/4-20 mA temperature transmitter engineered for common single-point measurement applications where space-efficient panel/cabinet mounting matters more than direct-in-sensor-head installation. 3-Point Calibration Certificate (Q4) and Custom Configuration of Software Parameters (C1) available. Intrinsic-Safety-only certifications — the 248R typically lives inside a customer-provided cabinet, so flameproof/XP variants aren't part of the line.

Request Quote →
Rosemount 3144P Temperature Transmitter # 3144P
Rosemount

3144P Temperature Transmitter

Emerson's flagship field-mount temperature transmitter. Dual-compartment housing isolates electronics from field wiring for serviceability without exposing the loop. HART 4-20 mA or FOUNDATION Fieldbus output, single or dual sensor input, ±0.10 °C digital accuracy, and advanced diagnostics (thermocouple degradation, min/max tracking, sensor drift alert). Pairs with the Rosemount 0085 Pipe Clamp Sensor for X-well non-intrusive surface temperature measurement.

Request Quote →
Rosemount 3144S Temperature Transmitter # 3144S
Rosemount

3144S Temperature Transmitter

Emerson's newest flagship field-mount temperature transmitter. Industry-leading 0.05 °C accuracy (Ultra performance class), 20-year stability, IEC 61508 safety certification, and Bluetooth configuration via ReadyConnect technology. Dual-compartment housing isolates electronics from field wiring. HART 4-20 mA output with full diagnostic coverage from sensor to control room. Pairs with the Rosemount 0085 Pipe Clamp Sensor for X-well non-intrusive surface temperature measurement, or with Rosemount 214C / 214A / 65 sensors and 114C / Twisted Square thermowells for traditional in-process measurement.

Request Quote →