5900C Compact Radar Level Gauge
SKU: 5900C
Compact version of the Rosemount 5900S tank-gauging radar — ±1 mm accuracy (slightly looser than the 5900S's ±0.5 mm) in a smaller, lower-cost form factor. SIL 2 certified, custody-transfer capable. Used in smaller tank farms, distribution terminals, and inventory-management applications where the 5900S would be over-spec. Same Tankbus FOUNDATION Fieldbus output. Pairs with the Rosemount 2240S for full level + temperature tank-gauging.
Contact us for pricing on this product.
Compact version of the Rosemount 5900S tank-gauging radar — ±1 mm accuracy (slightly looser than the 5900S's ±0.5 mm) in a smaller, lower-cost form factor. SIL 2 certified, custody-transfer capable. Used in smaller tank farms, distribution terminals, and inventory-management applications where the 5900S would be over-spec. Same Tankbus FOUNDATION Fieldbus output. Pairs with the Rosemount 2240S for full level + temperature tank-gauging.
The Rosemount 5900C Compact Radar Level Gauge # 5900C is manufactured by Rosemount. Valley Instrument Service is an authorized Rosemount dealer offering full sales support, NIST-traceable calibration, and expert technical assistance.
Have questions about this product?
Our team can help with product selection, specs, pricing, and application support.
Contact Us or Call (661) 327-8681Configure Your Rosemount 5900C Radar Level Gauge
Cost-optimized version of the Rosemount 5900S tank-gauging radar — ±1 mm or ±2 mm instrument accuracy (vs 5900S's ±0.5 mm Premium) in a simpler chassis. SIL 2 capable per IEC 61508 (no SIL 3 like the 5900S). Single-electronics only (no 2-in-1 redundancy). 10 GHz FMCW radar via 2-wire FOUNDATION Fieldbus Tankbus. Five antenna variants for different tank conditions: parabolic (1P), cone (1C, smaller-nozzle alternative to the 5900S horn), still-pipe array (1A), LPG/LNG (G1/G2, no G4), and 1/2-inch still-pipe (smallest pipe diameters). Custody transfer support limited (most variants are code 0 only). Pairs with the Rosemount 2240S for temperature; common in smaller tank farms and distribution terminals where the 5900S premium accuracy would be over-spec.
Required Specifications
15 of 15 selected- Performance Class:
- 11 — ±1 mm (0.04 in.) instrument accuracy
- Safety Certification (SIS):
- SS — IEC 61508 SIL 2 capable (requires 2410 with analog 4-20 mA or relay 1/2)
- Redundancy:
- 11 — None, single radar level gauge electronics (5900C has no 2-in-1 option)
- Tankbus: Power and Communication:
- FF — Bus-powered 2-wire FOUNDATION Fieldbus (IEC 61158)
- Hazardous Location Certification:
- I1I1 — ATEX Intrinsic Safety
- Custody Transfer Type Approval:
- 00 — None (5900C parabolic / cone / LPG variants do not support custody transfer)
- Level Measurement Method:
- 11 — 10 GHz FMCW radar technology
- Housing:
- AA — Standard enclosure, polyurethane-covered aluminum, IP 66/67
- Cable Entry / Conduit Connections:
- 11 — ½-14 NPT, female thread (1 plug included)
- Antenna Type:
- 1P1P — Parabolic antenna (premium fixed-roof without still-pipe; long range)
- Antenna Size:
- FF — 20 in. / DN 500, Ø=440 mm (parabolic 1P only)
- Antenna Material:
- SS — SST (AISI 316L / EN 1.4404, all antenna variants)
- Tank Seal:
- PFPF — PTFE with FEP fluoropolymer O-ring (parabolic 1P)
- Tank Connection:
- WEWE — Welded installation (parabolic 1P only)
- Antenna Options:
- VV — Proof test verification reflector (parabolic 1P, still-pipe 1A sizes 6/8/A/B; not with Options U1)
Rosemount is configurator-heavy and quote-only. Valley Instrument verifies option compatibility, lead time, and pricing before confirming your order.
Related Products

1208 Level + Flow Transmitter (80 GHz Basic)
Entry-level 80 GHz non-contacting radar for basic level and open-channel flow measurement. Compact NPT-mount transmitter, 4-20 mA HART output. Ideal for water/wastewater utility tanks, sump-pump level, basic process tanks where the 1408A would be over-spec. The lowest-cost Rosemount radar in the line.

1408A Level + Flow Transmitter (80 GHz)
Cost-effective 80 GHz non-contacting radar for basic level + flow applications in utilities, water-treatment, and general process. Compact form factor, 4-20 mA HART output, fixed-mount lens antenna. The entry-level 80 GHz Rosemount radar — when you need 80 GHz beam-angle advantage but don't need the 3408/5408 option flexibility.

1408H Hygienic Non-Contacting Radar Level (80 GHz)
Hygienic-process 80 GHz non-contacting radar level transmitter for Food, Beverage, Pharmaceutical, Biotech, and Cosmetics. Tri-Clamp, DIN-A, and DIN-B sanitary process connections with polished SST wetted parts (3-A and EHEDG compliant). Compact form factor (drop-in retrofit for legacy hygienic level instruments). Same 80 GHz beam-angle advantage as the 3408 / 1408A for tanks with internals.

3408 Non-Contacting Radar Level Transmitter (80 GHz)
High-frequency 80 GHz FMCW non-contacting radar level transmitter — narrow beam angle (typically 4°) eliminates interference from tank internals (agitators, ladders, heating coils) that confuses lower-frequency radars. Same antenna / process-connection / material variety as the 5408 but with the 80 GHz beam-shape advantage for challenging tank geometries. Both liquid and solids applications, including granular materials and aggregates where lower-frequency 26 GHz struggles.