Skip to content
(661) 327-8681
Valley Instrument
Rosemount 3051SFA Annubar Flow Meter
Rosemount

3051SFA Annubar Flow Meter

SKU: 3051SFA

Built to order. Configure below for an exact part number and quote.

Calibration Available
Nationwide Shipping
Expert Support

Configure Your Rosemount 3051SFA ProBar Annubar Flow Meter

Pre-assembled DP flow meter combining the Rosemount 485 Annubar averaging-pitot primary element with the Rosemount 3051S pressure transmitter. Best for line sizes ≥ 2 in where orifice plates introduce excessive permanent pressure loss. Lower installation cost than orifice for large lines (no flange unions, no bolted-in plates). HART or FOUNDATION Fieldbus output. Suitable for liquid, gas, or steam.

Required Specifications

18 of 18 selected
1
Transmitter Measurement Type*
D
2
Fluid Type*
L
3
Annubar Type*
P
4
Sensor Material*
S
5
Sensor Size*
1
6
Line Size*
020
7
Pipe ID Range*
A
8
Mounting Type*
T1
9
Pipe & Mounting Assembly Material*
0
10
Pipe Orientation*
H
11
Opposite Side Support*
0
12
Temperature Measurement*
0
13
Transmitter Connection Platform*
7
14
Differential Pressure Range*
3
15
Static Pressure Range*
A
16
Transmitter Output*
A
17
Transmitter Housing*
1A
18
Transmitter Performance Class*
2
Rosemount 3051SFA ProBar Annubar Flow Meter Part Number
3051SFADL020A0HPS1T100073AA1A2
Configured list price:$6,309.38Rosemount list price. Your Valley sales engineer confirms final pricing on the quote.Emerson adds a 4.9% Rosemount surcharge (effective Sep 1, 2026), about $309.16 on this configuration, as a separate line on the order.
Configuration Summary: Rosemount 3051SFA ProBar Annubar Flow Meter
Base: $5,092.25
Transmitter Measurement Type:
DDifferential Pressure
Fluid Type:
LLiquid
Line Size:
0202in (50mm)+$211.10
Pipe ID Range:
A1.784 to 1.842-in. (45.3 to 46.8 mm) / 2.648 to 2.752-in. (67.3 to 69.9 mm) / 4.438 to 4.572-in. (112.7 to 116.1 mm) / 5.250 to 5.473-in. (133.4 to 139.0 mm) / 8.767 to 9.173-in. (222.7 to 233.0 mm)
Pipe & Mounting Assembly Material:
0No Mounting (Customer Supplied)
Pipe Orientation:
HHorizontal Piping
Annubar Type:
PPak-Lok
Sensor Material:
S316 Stainless Steel
Sensor Size:
1Sensor size 1
Mounting Type:
T1Compression/Threaded Connection+$296.52
Opposite Side Support:
0No opposite side support or Packing Gland (Required for Pak-Lok, Flange-Lok
Temperature Measurement:
0No Temperature Sensor
Transmitter Connection Platform:
7Remote-mount NPT Connections
Differential Pressure Range:
30 to 1000 in H2O (0 to 2.5 bar)
Static Pressure Range:
ANone
Transmitter Output:
A4-20 mA with digital signal based on HART® protocol
Transmitter Housing:
1APlantWeb housing / aluminum / 1/2 - 14 NPT conduit entry+$560.53
Transmitter Performance Class:
2Classic: 1.1% flow rate accuracy, 8:1 flow turndown, 5-yr stability+$148.98

Rosemount is configurator-heavy and quote-only. Valley Instrument verifies option compatibility, lead time, and pricing before confirming your order.

Related Products

Rosemount 2051CFC Compact Orifice Flow Meter # 2051CFC
Rosemount

2051CFC Compact Orifice Flow Meter

Pre-assembled DP flow meter on the 2051C platform — combines a 2051C-platform DP transmitter, a Rosemount 405C compact conditioning orifice plate, and a 305 manifold in one factory-assembled, pre-calibrated package. No field assembly, no leak-checking, no separate piping for impulse lines. Drop in between standard process flanges and start measuring. Best for general-purpose closed-loop control and monitoring applications where the 3051C / 3051S premium platforms would be over-spec.

Request Quote →
Rosemount 3051CFC Compact Orifice Flow Meter # 3051CFC
Rosemount

3051CFC Compact Orifice Flow Meter

Pre-assembled DP flow meter on the 3051C platform — combines a 3051C Coplanar pressure transmitter, a 405C compact conditioning orifice plate, and a 305 manifold in one factory-assembled package. The 3051C platform adds graphical back-lit display option, Bluetooth configuration, multivariable inputs, and broader output protocol support (HART, WirelessHART, FOUNDATION Fieldbus). Available up to 12 in. (300 mm) line size for gas, liquid, and steam service. The midstream / downstream-grade DP flow meter for plants standardized on the 3051C transmitter.

Request Quote →
Rosemount 3051CFP Integral Orifice Flow Meter # 3051CFP
Rosemount

3051CFP Integral Orifice Flow Meter

Pre-assembled DP flow meter on the 3051C platform with a 1195 integral orifice primary element — engineered for highly accurate flow measurement in small line sizes (0.5 - 1.5 in. / 15 - 40 mm). Self-centering integral orifice plate eliminates the centering uncertainty of field-installed plates. Best for lab-scale, sample-conditioning, pilot-plant, and small-line process flow where standard 4-in.-and-up DP flow meters are too coarse. Same 3051C platform features as the 3051CFC: HART, Bluetooth, WirelessHART, FOUNDATION Fieldbus.

Request Quote →
Rosemount 3051SFC Compact Orifice Flow Meter # 3051SFC
Rosemount

3051SFC Compact Orifice Flow Meter

Pre-assembled DP flow meter on the 3051S Scalable platform with a 405C compact conditioning orifice — drops in between existing flanges for best-in-class flow measurement in gas, liquid, and steam service. Same 3051S electronics platform as the 3051SFA / 3051SFP: extreme stability, SIL 2/3 capability with QS, advanced diagnostics, all output protocols. The compact-orifice variant for general-purpose measurement on lines too large for integral orifice (3051SFP) but where annubar (3051SFA) low-pressure-loss isn't needed.

Request Quote →